Automated internal perfusion with the Port-a-Patch

Released on = February 26, 2007, 8:26 am

Press Release Author = Nanion Technologies

Industry = Biotech

Press Release Summary = Nanion Technologies introduces the Internal Perfusion System
for the Port-a-Patch; a completely unique device for rapid, continuous and automated
exchange of internal solutions during patch clamp recordings.

Press Release Body = PressRelease: Automated internal perfusion with the Port-a-Patch
Munich, 26th February 2007
Nanion Technologies introduces the Internal Perfusion System for the Port-a-Patch; a
completely unique device for rapid, continuous and automated exchange of internal
solutions during patch clamp recordings.
Using the internal perfusion system, ion channels regulated by internal binding
sites for second messengers can be easily modulated or compounds acting on the
internal side of the membrane like e.g. hERG active substances can be directly
applied internally.
Planar patch clamp chips offer the possibility to perfuse the extracellular as well
as the intracellular side of the cell membrane. With conventional patch-clamping,
the latter is commonly very difficult, due to the laborious set ups required and the
diffusion limited perfusion within the long tapered shaft of a patch pipette.

"The Internal Perfusion System for the Port-a-Patch offers unprecedented
possibilities for patch clamp investigations of substances affecting a cell from the
inside. High quality whole-cell recordings can be collected during perfusion of the
cell's internal membrane side. This device is totally unique in its experimental
possibilities and ease-of-use." says Andrea Brüggemann, CSO and managing director,
Nanion Technologies.

The automated Internal Perfusion System is an add-on to the Port-a-Patch with a
dedicated chip holder containing fluidics and a specially designed shielding
compartment with an inverted electrode arrangement for bath and reference electrode.
The Internal Perfusion System is a "plug-and-play" device, fully compatible the
Port-a-Patch as well as Nanion's 8-channel perfusion system.

The Internal Perfusion System for the Port-a-Patch has been used for the internal
administration of compounds to different ion channel types, for example hERG, Kv1.3.
Also, the system has been used for bilayer recordings of gramicidin, investigating
the changes of current amplitudes as a response to changes in solution compositions.
Some of the collected data can be found in NanionNotes7, available on our website
www.nanion.de.

The ability to change the internal solution several times, along with long lasting
and stable whole cell or bilayer recordings possible with the Port-a-Patch, opens up
to new experimental possibilities for a broad range of ion channel studies and will
prove to be a useful tool in ion channel research.


To check out and learn more about the new Internal Perfusion System for the
Port-a-Patch, please come by our booth 469,471 at the Biophysical Meeting in
Baltimore, MD, USA! See you there!


About Nanion:
Nanion Technologies (Germany) is a spin-off from the Center for Nanoscience (CeNS)
of the University of Munich and is dedicated to providing flexible and customized
solutions for ion channel research both in industry and academia. With the
miniaturized NPC©-1 port-a-patch ©, Nanion offers the world's smallest patch-clamp
workstation. This innovative drug discovery technology makes patch clamp available
also to non-electrophysiologists. The NPC©-16 patchliner ©, which is available as a
2, 4 and 8 channel version additionally addresses the higher throughput requirements
for ion channel screening and is a valuable tool for


Web Site = http://www.nanion.de

Contact Details = Nanion Technologies
Erzgiessereistr. 4
80335 Munich
Germany
Tel: +49 89 218997972
Fax:+4989218997960
info@nanion.de
www.nanion.de

  • Printer Friendly Format
  • Back to previous page...
  • Back to home page...
  • Submit your press releases...
  •